Beckhoff · TwinCAT 2 NC
The value specified for the percentage weighting of the velocity pre-control is not allowed, as it must be within the range [0.0 ... 1.0]. This parameter, typically preset to 1.0 (100%), influences the feedforward control of velocity. An invalid value can lead to poor motion tracking, instability, or overshoots/undershoots.
Click steps to track your progress.
1. Access the velocity pre-control weighting parameter (e.g., P5-10) and set its value to be between 0.0 and 1.0 (e.g., 1.0 for 100% pre-control).
2. Verify the input method (e.g., HMI, software) handles decimal values correctly and is not inadvertently converting input (e.g., 100 to 100.0).
3. Review the system's tuning guidelines to determine the optimal pre-control weighting for the specific mechanical setup and application.
4. Perform a parameter download from the configuration software to the controller to ensure the corrected value is properly applied.
5. Monitor motor velocity response (e.g., using diagnostic D-01) after adjustment to ensure smooth motion and reduced tracking error.