E8029

Positive position limit exceeded

Bosch Rexroth · IndraDrive C Drive Controllers

What does E8029 mean?

The actual or commanded position has exceeded the configured positive software travel limit. This can lead to the machine reaching its mechanical hard stop or unexpected motion.

Common Causes

  • Programmed motion or jog command attempts to move beyond the positive software travel limit.
  • Incorrectly set positive software limit parameter.
  • Loss of position feedback or incorrect encoder scaling, leading to misinterpretation of actual position.
  • Mechanical overtravel due to inertia or incorrect braking.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Verify the positive software travel limit parameter in the drive controller and ensure it is set correctly and safely for the application.

  2. 2

    Check the commanded position values in the motion program to ensure they do not exceed the positive travel limit.

  3. 3

    Inspect the position feedback system for encoder accuracy and scaling parameters.

  4. 4

    Manually jog the axis to a safe position within the valid travel range.