ErrorLib — Industrial Fault Code Library

Disclaimer: ErrorLib is an independent technical reference tool. While we aim for accuracy, always verify with the manufacturer’s official service manuals before performing maintenance on industrial equipment. ErrorLib is not affiliated with the brands listed.

E8034

Emergency-Stop

Bosch Rexroth · IndraDrive C Drive Controllers

What does E8034 mean?

An Emergency Stop condition has been detected, causing an immediate and controlled shutdown of the drive and potentially the entire machine. This is a critical safety response.

Common Causes

  • Emergency Stop button pressed.
  • Activation of an external safety device (e.g., light curtain, safety gate switch).
  • Fault in the emergency stop circuit wiring or components.
  • Safety PLC or logic error triggering the Emergency Stop.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Identify and release the activated Emergency Stop button or reset the safety device that triggered the E-Stop.

  2. 2

    Verify the integrity of the Emergency Stop circuit wiring, including all series-connected safety contacts.

  3. 3

    Check the status of all safety inputs to the drive or safety PLC to identify which one initiated the E-Stop.

  4. 4

    Reset the drive and machine control system once the E-Stop condition is cleared and confirmed safe.

Browse all codes in this manual (66)
Verified technical data. Last updated: April 2026

Related Faults

E2051Motor overtemp. prewarningE2053Target position out of travel rangeE2054Not homed
Source: Bosch Rexroth IndraDrive C Drive Controllers
Open Manual (Page 316)Search more codes in this manual