ErrorLib — Industrial Fault Code Library

Disclaimer: ErrorLib is an independent technical reference tool. While we aim for accuracy, always verify with the manufacturer’s official service manuals before performing maintenance on industrial equipment. ErrorLib is not affiliated with the brands listed.

E8044

Negative travel range limit switch activated

Bosch Rexroth · IndraDrive C Drive Controllers

What does E8044 mean?

The negative hardware travel limit switch has been activated, indicating that the axis has reached its maximum physical travel in the negative direction. This typically results in a controlled stop.

Common Causes

  • Programmed motion or jog command caused the axis to activate the negative limit switch.
  • Incorrectly set software limits, allowing motion to reach the hardware limit.
  • Mechanical overtravel due to inertia or incorrect braking after the software limit.
  • Faulty negative limit switch or its wiring.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Manually jog the axis in the positive direction to clear the limit switch and return to a safe operating range.

  2. 2

    Verify the negative software travel limit parameter in the drive controller and adjust it to be inside the hardware limit.

  3. 3

    Inspect the negative limit switch for physical damage, proper mounting, and verify its wiring for continuity.

  4. 4

    Check the motion program for any commands that might cause the axis to intentionally or unintentionally hit the limit switch.

Browse all codes in this manual (66)
Verified technical data. Last updated: April 2026

Related Faults

E2051Motor overtemp. prewarningE2053Target position out of travel rangeE2054Not homed
Source: Bosch Rexroth IndraDrive C Drive Controllers
Open Manual (Page 317)Search more codes in this manual