Bosch Rexroth · IndraDrive C Drive Controllers
The analog signal amplitude from encoder 1 is outside the expected range, indicating a problem with the encoder, its cabling, or the drive's input circuit. This affects position and velocity feedback accuracy.
Click steps to track your progress.
Inspect the cabling for encoder 1 for physical damage, proper shielding, and secure connections. Check for proper signal ground connections.
Verify the encoder's power supply voltage at the encoder terminals. Incorrect voltage can affect signal amplitude.
If possible, use an oscilloscope to measure the differential signal amplitude of the encoder at the drive's input. Compare with the encoder's specifications.
Check drive parameters related to encoder input configuration, such as termination settings. If the fault persists, the encoder or drive input may be defective.