Danfoss · VLT HVAC Drive High Power
An internal fault occurred during the Automatic Motor Adaptation (AMA) process. While a single occurrence might be transient, repeated occurrences suggest a more persistent issue within the drive's control logic or its interaction with the motor, potentially heating the motor due to repeated attempts.
Click steps to track your progress.
1. Cycle power to the drive (power off for 30 seconds, then power on) and retry the AMA.
2. Perform a factory reset of the drive (e.g., P14-20 = 2) and carefully re-enter all motor and application parameters.
3. Verify incoming AC line voltage stability (L1, L2, L3) using a voltmeter and check for transient sags or surges.
4. Check for proper grounding of the drive and motor, ensuring ground wire resistance is below 1 Ohm.
5. If possible, attempt AMA with a different known-good motor (if available) to rule out motor-specific interactions.