Indramat · dds 2.1 digital servo drive User Manual
A Class 1 Diagnostic indicating a shutdown error because the motor has reached an excessively high temperature. The DDS 2.1 drive is notified via a thermal resistor in the motor windings. This shutdown typically follows a 'Motor Over Temperature Warning' (diagnostic '51') that persisted for more than 30 seconds. The drive immediately enters a shutdown mode according to parameter P-O-0007, Error Reaction. This condition is reset only after the cause is cleared and the command 'Reset Class 1 Diagnostics' is received via the service channel.
Click steps to track your progress.
Check motor and drive sizing against the actual application requirements for continuous and peak loads.
Inspect the mechanical system for any binding or excessive friction that could increase the motor's load.
Verify the integrity of the motor's thermal connection (e.g., PTC thermistor or KTY sensor) for short circuits or ground faults.
Monitor the motor current during operation and compare it against the motor's nominal current rating.
Ensure adequate ventilation and cooling for the motor itself, checking for blocked cooling fins or a faulty integral fan.