S-0-0011 Bit 4

Control Voltage Error

Indramat · dds 2.1 digital servo drive User Manual

What does S-0-0011 Bit 4 mean?

A Class 1 Diagnostic indicating an issue with the DDS 2.1 drive's internal control voltage supply. This often means that one or more internal low-voltage DC supplies (e.g., 24V, 5V) required for the control electronics are out of tolerance or absent, leading to a drive shutdown. The drive decelerates to zero speed and shuts down torque. This condition is reset only after the cause is cleared and the command 'Reset Class 1 Diagnostics' is received via the service channel.

Common Causes

  • Internal power supply fault within the DDS 2.1 drive.
  • Instability or loss of the external 24VDC supply connected to the drive's control terminals (if applicable).
  • Excessive load on auxiliary outputs supplied by the drive's internal control voltage.
  • Faulty wiring or poor connection to the control voltage input terminals.
  • Damaged control board components affecting voltage regulation.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Measure the external 24VDC control supply voltage at the drive's input terminals to confirm it is stable and within specification.

  2. 2

    Inspect control wiring and connections to the DDS 2.1 for loose terminals, damage, or corrosion.

  3. 3

    Disconnect non-essential auxiliary loads powered by the drive's control voltage to check if the error clears.

  4. 4

    Check the diagnostic LEDs or display on the DDS 2.1 for more specific indicators of internal power supply issues.

  5. 5

    If no external causes are found, internal drive component failure is likely, requiring professional diagnosis or replacement.