26046

Mains phase failure, KPP/KSP (axis)

KUKA KRC4 · Robot Controller

What does 26046 mean?

Failure of one or more mains phases supplying the KUKA KRC4 KPP/KSP device. This can lead to insufficient power, improper operation, or damage to the drive.

Common Causes

  • Interruption or loss of one or more phases in the incoming mains power supply.
  • Loose or damaged power leads connecting to the KUKA KRC4 KPP/KSP.
  • Issues with the KPP cabling, such as poor connections or conductor damage.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check the incoming mains power supply for phase continuity, correct voltage levels, and proper sequencing.

  2. 2

    Inspect the power leads connecting to the KUKA KRC4 KPP/KSP for damage or loose connections.

  3. 3

    Verify all KPP cabling for proper installation, connection, and integrity.

  4. 4

    Reinitialize the drive bus by performing a Power Off / Power On cycle for the KUKA KRC4 controller.

  5. 5

    If the fault persists after external checks, inspect the KUKA KRC4 KPP module.