26046

Mains phase failure, KPP/KSP (axis)

Kuka · KR C4 Operating Instructions

What does 26046 mean?

One or more mains phases supplying the KPP/KSP device have failed. This suggests an issue with the incoming AC power supply to the drive, potentially leading to incorrect operation or shutdown.

Common Causes

  • One or more phases of the main AC power supply to the KPP/KSP drive is absent or incorrect.
  • Improper connection of three-phase power.
  • Blown fuse or tripped breaker on the input power line.
  • Internal fault in the KPP/KSP power input stage.
  • Voltage imbalance between the phases.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check the power lead connected to the KPP for disconnections or physical damage.

  2. 2

    Inspect the KPP cabling for loose or damaged connections to the mains supply terminals.

  3. 3

    Reinitialize the drive bus by performing a Power Off / Power On cycle of the entire system.

  4. 4

    Check the KPP module itself for internal faults if mains supply is verified correct.

Browse all codes in this manual (23)