26118

Mains phase failure, KPP/KSP (axis)

Kuka · KR C4 Operating Instructions

What does 26118 mean?

A failure has been detected in one or more mains input phases supplying the KPP or KSP device for a specific axis. This indicates an issue with the incoming AC power supply to the drive, such as a blown fuse, tripped breaker, or open phase. Loss of a mains phase can cause imbalances, overheating, and prevent the drive from operating.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Inspect the power lead connecting to the KPP for damage, loose connections, or incorrect phasing.

  2. 2

    Inspect all KPP cabling, including input power terminals, for secure connections and integrity.

  3. 3

    Perform a Power Off / Power On cycle of the entire system to reinitialize the drive bus.

  4. 4

    Check the status indicators or diagnostics of the KPP device.

Browse all codes in this manual (23)