11000

Device could not be started within timeout

Kuka · ProfiNet Controller/Device 3.1

What does 11000 mean?

The PROFINET communication with the specified device ({Name}) failed to establish within the configured timeout period ({Timeout} ms). This indicates an issue preventing the device from initiating communication with the controller, potentially leading to system downtime.

Common Causes

  • The device failed to start within the specified timeout period.
  • Initialization process took too long, indicating a problem.
  • Hardware failure, configuration error, or software hang during startup.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Verify that the PROFINET device {Name} is powered on and its status indicators are normal.

  2. 2

    Inspect the network cable connection between the PROFINET controller and device {Name} for proper seating and integrity.

  3. 3

    Confirm that the PROFINET device name configured in WorkVisual for {Name} precisely matches the physical device's assigned name.

  4. 4

    Check the IP address and subnet mask settings for device {Name} in the PROFINET configuration to ensure they are correct and unique.