ErP

Keypad/Device Communication Abort

Lenze · 8200 Series

What does ErP mean?

A communication abort has occurred between the keypad and the standard device (e.g., fault codes ErP0 through ErP19), indicating a failure in data exchange. The specific cause can vary. This prevents proper interaction with the device via the keypad and requires expert assistance for diagnosis.

Common Causes

  • Loose or damaged cable connection between the keypad and the drive controller.
  • Keypad not securely seated in its mounting slot or having bent pins on the connector.
  • Electrical noise interfering with the serial communication between the keypad and the device.
  • Faulty keypad unit or damaged communication port on the drive controller.
  • Firmware incompatibility or corruption on either the keypad or the drive controller.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Disconnect and re-connect the keypad cable, ensuring it is fully seated and secured at both the keypad and the drive controller.

  2. 2

    Carefully inspect the keypad connector pins and the drive's communication port for any physical damage, bent pins, or debris.

  3. 3

    Check for external sources of electrical interference near the keypad cable, such as unshielded power cables or contactors.

  4. 4

    Test with a known-good keypad if available, or attempt to connect to the drive using an alternative communication method (e.g., a PC via a service port).

  5. 5

    Verify the firmware versions of both the keypad and the drive controller for compatibility, consulting the device manual if necessary.

Browse all codes in this manual (40)
Verified technical data. Last updated: April 2026