OH

Heatsink Overtemperature

Lenze · 8200 Series

What does OH mean?

The controller's heatsink temperature has exceeded its safe operating limit (either >85°C or >80°C), typically due to high ambient temperature, blocked airflow, or excessive drive load. A dirty heatsink or high currents during acceleration can also contribute. Sustained overtemperature will lead to derating, thermal shutdown, and reduced component lifespan.

Common Causes

  • High ambient temperature surrounding the drive exceeding its specified operating limit (e.g., >40°C).
  • Blocked or restricted airflow to the heatsink fins due to dust, debris, or improper enclosure design.
  • Cooling fan failure (e.g., FAn1 fault not yet triggered) reducing heat dissipation.
  • Excessive drive load leading to sustained high current output, generating more heat.
  • Dirty heatsink fins restricting heat transfer from the power modules.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    1. Measure the ambient temperature immediately surrounding the drive and ensure it is within the drive's specified operating range.

  2. 2

    2. Disconnect mains power and clean the heatsink fins thoroughly with compressed air to remove dust and debris.

  3. 3

    3. Verify the operation of all cooling fans within the drive by observing rotation and airflow once power is restored.

  4. 4

    4. Ensure proper ventilation within the electrical enclosure, checking for blocked vents or insufficient spacing around the drive.

  5. 5

    5. Monitor the drive's output current (e.g., C0004) to confirm it is within the drive's nominal rating for continuous operation.