Omron · MX2 Inverter
This warning indicates that the seventh point of the free setting V/f curve (b112) is set higher than the frequency lower limit (A062). This creates an inconsistent lower boundary for the V/f characteristic, potentially restricting the minimum V/f output.
Click steps to track your progress.
Read the current value of parameter b112 (Free setting V/f curve frequency point 7) and parameter A062 (Frequency lower limit) from the HMI or control software.
Adjust parameter b112 to be less than or equal to the desired A062, ensuring the V/f curve point respects the frequency lower limit.
Alternatively, if a higher lower limit is intended for operation, increase parameter A062 to a value greater than or equal to b112, based on application requirements.
Store the updated parameters in the drive's memory and then perform an inverter reset to apply the changes.