Omron · MX2 Inverter
This fault indicates an overcurrent condition that occurred under operating circumstances other than constant speed, acceleration, or deceleration. This general overcurrent trip mechanism acts as a catch-all for various abnormal current events, protecting the inverter from sustained high current levels.
Click steps to track your progress.
Inspect the driven machine for sudden load impacts or mechanical events that could cause instantaneous current surges.
Verify proper shielding and grounding of motor cables to the inverter and motor frames according to manufacturer specifications.
Check for loose connections at inverter output terminals U, V, W and motor terminals.
Monitor input AC voltage at inverter terminals L1, L2, L3 using a multimeter for stability and correct phase sequence.
Perform a no-load run test with the motor decoupled to isolate the inverter/motor from mechanical load issues, monitoring current (d0-03).