Omron · MX2 Inverter
This fault indicates a problem with the inverter's built-in EEPROM memory, often caused by electrical noise, power fluctuations, or excessive temperature. When this error occurs, the inverter trips and turns off its output to the motor to prevent further data corruption or erratic behavior.
Click steps to track your progress.
Cycle the inverter's main power supply off for 5 minutes, then back on to attempt a soft reset of the EEPROM.
Inspect control wiring for proper shielding and grounding, ensuring separation from power cables to reduce EMI.
Measure the control power supply voltage (e.g., at terminals +24V, CM) using a multimeter to confirm stability.
Check the inverter's internal cooling fan operation and clear any dust or obstructions from heatsinks to ensure adequate cooling.
Perform a factory reset (e.g., Parameter P9-02 set to 2) to reinitialize EEPROM data, then re-enter application parameters.