HCF

Hardware Configuration Error

Schneider Electric · Altivar Machine ATV320 Variable Speed Drive

What does HCF mean?

A detected error in the hardware configuration, possibly related to 'cards pairing'. This means the drive's internal components or installed option cards are not recognized correctly or are incompatible. This can prevent the drive from operating or utilizing specific features.

Common Causes

  • Mismatch between hardware components and the configured system settings.
  • Incorrect or missing option modules detected during initialization.
  • Firmware version incompatible with installed hardware.
  • Physical connections of hardware modules are loose or incorrect.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Verify all internal boards and option cards are securely seated in their respective slots.

  2. 2

    Check for compatible versions of installed hardware components against the drive model and firmware.

  3. 3

    Power cycle the drive to allow for hardware re-detection and initialization.

  4. 4

    If a new component was recently installed, remove it and test to see if the fault clears.

Browse all codes in this manual (60)
Verified technical data. Last updated: April 2026

Related Faults

ASFAngle ErrorCFFIncorrect ConfigurationCFI2Configuration Transfer Error
Source: Schneider Electric Altivar Machine ATV320 Variable Speed Drive
View Official PDFSearch more codes in this manual