An unspecified internal error has occurred within the MOVIMOT® inverter. This type of error usually requires specialized diagnostic tools and expertise.
Click steps to track your progress.
Verify input supply voltage (L1, L2, L3) at the MOVIMOT® inverter's main power terminals against the rated nominal voltage.
Inspect the motor cable for any visible damage, chafing, or signs of stress, and check all motor connections (U, V, W, PE) for tightness and proper termination.
Check all operational and motor-specific parameter settings within the MOVIMOT® inverter using SEW diagnostic software (e.g., MOVITOOLS® MotionStudio) for correctness and compare with the last known good configuration.
Measure the insulation resistance of the motor windings to ground and phase-to-phase with the MOVIMOT® inverter disconnected, ensuring it meets manufacturer specifications.
Perform a complete power cycle of the MOVIMOT® inverter by disconnecting and reconnecting the main power supply, then monitor for fault reoccurrence.