There is a discrepancy between the raw position data and the track counter of absolute Encoder 1, suggesting an internal inconsistency in position tracking. This can lead to incorrect position readings and unstable drive operation. Unresolved, it can cause erratic movements or positioning errors.
Click steps to track your progress.
Compare the raw encoder position data (P7-04) with the processed track counter value (P2-01) for sudden jumps or inconsistencies.
Inspect the encoder cable shielding for proper connection to the drive's ground terminal (SG) and check for continuity (less than 1 Ohm).
Verify that the numerator (P7-05) and denominator (P7-06) for encoder scaling are correctly configured according to the encoder's resolution.
Perform a physical inspection of the encoder mounting for looseness or signs of excessive vibration.
Attempt to re-initialize the encoder's internal position (refer to drive/encoder manual, often involving parameter P7-00).