Siemens · SINUMERIK 828D
This fault indicates that the drive-based Safety Integrated (SI) function in the Control Unit (CU) has detected an anomaly and initiated a STOP A, which involves pulse suppression via the safety shutdown path. This can be due to an unsuccessful forced checking procedure of the safety path, or a subsequent response to a monitoring channel defect (F01611). The fault value provides more detail, such as stop requests, pulse suppression issues, or feedback discrepancies. This safety-critical fault immediately inhibits motor operation to prevent hazardous situations.
Click steps to track your progress.
1. Identify the specific cause code associated with STOP A in the drive's diagnostic buffer (e.g., r0947, r949) to pinpoint the source.
2. Verify the status of all safety input signals (e.g., STO, SLS via terminals X150.1-X150.4) using a voltmeter to confirm their correct state.
3. Perform an online safety diagnostics check using the engineering tool (e.g., TIA Portal Safety Integrated Editor) to read detailed safety fault information.
4. Cycle power to the drive (main power off/on) to reset the Control Unit and observe if the fault persists immediately upon restart.
5. If the fault reoccurs without external cause, consider replacing the Control Unit as it indicates an internal hardware failure.