Siemens · SINUMERIK 828D
An alarm indicating that the filtered, steady-state value of the line supply voltage has dropped below the alarm threshold set by p0282. This is a warning condition, not a shutdown, meaning there is no immediate reaction. The alarm value (r2124) shows the current line supply voltage.
Click steps to track your progress.
1. Measure the incoming AC line supply voltage (L1-L2, L2-L3, L3-L1) at the infeed power terminals using a power quality analyzer to log voltage variations over time.
2. Review parameter P0282 (DC link voltage alarm threshold) and compare it to the system's nominal voltage and acceptable operating range. Adjust if set too aggressively.
3. Inspect power cabling from the main distribution to the machine for correct sizing (gauge) and secure connections, checking for signs of overheating.
4. Monitor the actual DC link voltage (r0026) during machine operation, noting the specific values when the alarm is triggered.
5. Consult with facility management to investigate broader electrical network stability and consider installing a voltage stabilizer if fluctuations are frequent.