Siemens · SINUMERIK 828D
An error occurred during the spindle's gear stage change operation. The specific cause is indicated by an error code (%3). This fault disables NC Start in the channel and sets interface signals, requiring attention to resolve the conflict.
Click steps to track your progress.
1. Inspect the mechanical gear shifting mechanism visually for obstructions, wear, or damage, checking for smooth movement of linkages.
2. Measure the output signals of all gear stage position sensors (e.g., 24VDC) at the PLC input terminals, verifying status changes during manual gear shifts.
3. Test the gear shifting actuator's functionality by commanding individual movements (e.g., activating solenoid valves) and observing physical response.
4. Verify spindle speed (r0063) before and during attempted gear changes, ensuring it is within the permissible window (e.g., 0 RPM or specified synchronization speed).
5. Review drive parameters related to gear stage control (e.g., P1-60, P1-61, P1-62, P1-63 for gear ratios) and compare with machine documentation.
6. Perform a manual gear change operation (if possible via HMI or diagnostic tool) to isolate the issue between automatic control and mechanical function.