This alarm indicates that a new SDB (System Data Block) with a modified configuration has been provided for the PROFIBUS/PROFINET bus. Similar to 380502, the new settings will only be activated upon the next bus power-up. This is an informational alarm requiring a system restart to apply the updated configuration, ensuring correct bus operation and avoiding potential communication errors.
Click steps to track your progress.
1. Acknowledge the alarm and determine if the bus configuration change was an intentional act (e.g., new project download).
2. Upload the active hardware configuration from the PLC into the engineering software to identify discrepancies with the existing offline project.
3. Review the PLC's diagnostic buffer (e.g., using Step 7 or TIA Portal) for further details regarding the specific SDB change.
4. If the change is expected, download the updated and verified hardware configuration from the engineering software to the PLC.
5. Perform a full Power OFF/ON cycle of the PLC and all associated PROFIBUS/PROFINET devices to ensure the new SDB is fully activated and initialized.
6. Verify operational status of all PROFIBUS/PROFINET devices after the configuration download by monitoring their diagnostic LEDs and process values.