Yaskawa · VS-616G5 Variable Speed Drive
This fault indicates an issue with the run command or a conflict in the command source (e.g., local/remote, digital input, serial). It prevents the inverter from starting or continuing operation. This can happen if the run command is unexpectedly lost, or if there's a discrepancy in how the inverter is commanded to run.
Click steps to track your progress.
Verify parameter P0-01 (Run Source Selection) is set correctly for the intended run command source (e.g., 0 for Keypad, 1 for Digital Inputs, 2 for Serial).
Measure voltage at the assigned digital input terminal (e.g., S1-SC) when a run command is expected (e.g., 24VDC for ON).
Check the state of external safety interlocks or E-stop buttons connected to the inverter's control terminals.
If using serial communication, confirm the run command bit (e.g., Bit 0 of register 0001h for MODBUS) is being written correctly.
Cycle power to the inverter and re-attempt the run command from a single, verified source.