SP0022
Spindle Amplifier Current Overload
Fanuc · AC Spindle Motor Alpha i-Beta i Series Parameters
What does SP0022 mean?
The spindle amplifier is experiencing an overcurrent condition. This can be caused by excessive load on the motor, a short circuit, or incorrect current limits.
Common Causes
- Excessive mechanical load on the spindle motor.
- Short circuit within the spindle motor windings.
- Amplifier output transistors have failed.
- Incorrect motor tuning parameters (e.g., P5-XX related to current limits).
Repair Steps & Checklist
Click steps to track your progress.
- 1
Measure spindle motor current during operation using P5-04.
- 2
Inspect motor for bearing issues or mechanical binding.
- 3
Perform motor winding resistance test between phases (U, V, W).
- 4
Review and adjust current limit parameters (e.g., P5-02, P5-03) if set too low.
Verified technical data. Last updated: March 2026
Related Faults
Source: Fanuc AC Spindle Motor Alpha i-Beta i Series Parameters