0434
Velocity Loop Integral Gain Overflow
Fanuc · Alpha i Series Servo Amplifier
What does 0434 mean?
This invalid parameter setting alarm indicates that the internal calculation value of the velocity loop integral gain has overflowed. This typically occurs when the parameter setting for the integral gain is excessively high, leading to calculation errors.
Common Causes
- Integral term in the velocity control loop has exceeded its maximum allowable value.
- Persistent steady-state error in velocity control.
- Incorrect tuning of velocity integral gain (P04-11).
- External disturbance requiring excessive integral correction.
Repair Steps & Checklist
Click steps to track your progress.
- 1
Decrease the value of the velocity loop integral gain parameter.
Verified technical data. Last updated: March 2026
Related Faults
Source: Fanuc Alpha i Series Servo Amplifier