0535

Dead Zone Compensation Parameter Overflow

Fanuc · Alpha i Series Servo Amplifier

What does 0535 mean?

This invalid parameter setting alarm indicates that the internal calculation value of a parameter related to dead zone compensation has overflowed. This typically happens when the compensation setting is too high, leading to mathematical limits being exceeded.

Common Causes

  • Dead zone compensation parameter calculation has overflowed.
  • Excessive mechanical slack or play in the drive train.
  • Improper dead zone compensation tuning (P04-12).
  • Variable friction characteristics.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Decrease the setting of the parameter related to dead zone compensation to the extent that the invalid parameter setting alarm is no longer caused.

Browse all codes in this manual (101)