SV0488

SELF TEST OVER TIME

Fanuc · Alpha i Series Servo Amplifier

What does SV0488 mean?

The MCC off Test was not completed within the time specified by parameter No. 1946. This indicates a potential issue with the MCC (Motor Contactor) contact operation, its wiring, or an inappropriately set test time.

Common Causes

  • Internal self-test routine of the control system took longer than the defined time limit.
  • CPU overload or slow response impacting internal diagnostics.
  • Memory access issues during self-test.
  • Complex operation slowing down system initialization.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Inspect the MCC (Motor Contactor) contact for proper operation, mechanical integrity, and wear.

  2. 2

    Verify the value of parameter No. 1946, which defines the maximum allowable time for the MCC off Test, and adjust if necessary.

Browse all codes in this manual (101)
Verified technical data. Last updated: March 2026

Related Faults

Source: Fanuc Alpha i Series Servo Amplifier