LOGIC FAILURE #1
Kone · Elevator Control
What does 1019 mean?
A logic failure of type #1 has occurred in the motor controller (codes 1019, 2019, 3019). This indicates an internal control logic error, preventing correct operation. The specific lift reaction is controller dependent.
Common Causes
- Internal controller logic processing error.
- Corrupted program memory or runtime data.
- Hardware fault affecting logic circuits or CPU functionality.
Repair Steps & Checklist
Click steps to track your progress.
- 1
Verify main AC/DC supply voltage to the motor controller input terminals against nominal specifications and stability.
- 2
Check and compare current operational parameters and configuration settings of the motor controller against the documented system backup or factory defaults.
- 3
Inspect and verify the operational status of critical inputs such as encoder feedback, limit switches, and safety circuit signals via the controller's diagnostic interface.
- 4
Perform a controlled power cycle of the motor controller after safely stopping the elevator, observing for recurrence of the error.