53

53 Drive Reverse Coil Fault

Kone · Elevator Control

What does 53 mean?

A fault has been detected in the drive reverse coil, indicating an electrical issue with the solenoid responsible for reverse motion. This disables both lifting and driving functions.

Common Causes

  • Drive reverse coil open circuit, short circuit, or high resistance.
  • Damaged wiring or loose connections to the drive reverse coil.
  • Control circuit failure attempting to activate the coil.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Verify the nominal operating voltage for the drive reverse coil.

  2. 2

    Measure the voltage across the terminals of the drive reverse coil when it should be active.

  3. 3

    Inspect all wiring and connections leading to and from the drive reverse coil for damage, looseness, or signs of overheating.

  4. 4

    Measure the resistance of the drive reverse coil itself, comparing it to specifications or a known good value.

  5. 5

    Check for continuity across any protective fuses or circuit breakers in the drive reverse coil circuit.

Browse all codes in this manual (60)
Verified technical data. Last updated: March 2026

Related Faults