56

56 Steer Right Coil Fault

Kone · Elevator Control

What does 56 mean?

A fault has been detected in the steer right coil, indicating an electrical issue with the solenoid responsible for steering right. This disables both lifting and driving functions.

Common Causes

  • Steer right coil open circuit, short circuit, or high resistance.
  • Damaged wiring or loose connections to the steer right coil.
  • Control circuit failure attempting to activate the coil.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Inspect all wiring, connectors, and terminals associated with the 'Steer Right Coil' solenoid for any visible damage, disconnections, or corrosion.

  2. 2

    With power safely disconnected, measure the resistance of the 'Steer Right Coil' solenoid winding and compare the reading to the manufacturer's specified value.

  3. 3

    Measure the supply voltage at the 'Steer Right Coil' solenoid terminals while the steer right function is commanded, ensuring it matches the system's nominal operating voltage.

  4. 4

    Verify relevant diagnostic parameters, input/output status, and historical fault logs within the Kone Kone Elevator Control system for additional clues or related errors.

Browse all codes in this manual (60)
Verified technical data. Last updated: March 2026