MR2

Alarm Space 2 Violation

Kuka · KK53Y Servo Motor

What does MR2 mean?

The MR2 signal indicates a violation of monitoring space 2. A '0' state on this signal means that monitoring space 2 is currently being infringed upon. If monitoring space 2 is intentionally inactive, the system considers it violated by default, and the associated safe output MR2 will be in the '0' state.

Repair Steps

  1. 1

    Identify the configured boundaries for monitoring space 2 in the robot's programming environment (e.g., using KUKA WorkVisual).

  2. 2

    Physically inspect the robot's current position and ensure no part of the manipulator, external axes, or tooling is entering or has entered the defined monitoring space 2.

  3. 3

    If monitoring space 2 is intended to be inactive, verify this configuration in WorkVisual and acknowledge that the MR2 signal will default to a '0' (violated) state.

Browse all codes in this manual (17)
Verified technical data. Last updated: March 2026