MR8

Alarm Space 8 Violation

Kuka · KK53Y Servo Motor

What does MR8 mean?

The MR8 signal indicates a violation of monitoring space 8. A '0' state on this signal means that monitoring space 8 is currently being infringed upon. If monitoring space 8 is intentionally inactive, the system considers it violated by default, and the associated safe output MR8 will be in the '0' state.

Repair Steps

  1. 1

    Identify the configured boundaries for monitoring space 8 in the robot's programming environment (e.g., using KUKA WorkVisual).

  2. 2

    Physically inspect the robot's current position and ensure no part of the manipulator, external axes, or tooling is entering or has entered the defined monitoring space 8.

  3. 3

    If monitoring space 8 is intended to be inactive, verify this configuration in WorkVisual and acknowledge that the MR8 signal will default to a '0' (violated) state.

Browse all codes in this manual (17)
Verified technical data. Last updated: March 2026