13037
Profinet controller stack cannot be started
Kuka · ProfiNet Controller/Device 3.1
Hva betyr 13037 ?
The PROFINET controller stack failed to start. The root cause is an incorrect parameterization of the PROFINET firmware, specifically an issue within the 'bas_cm_api.xml' configuration file. This prevents the robot controller from acting as a PROFINET controller.
Vanlige årsaker
- The Profinet controller stack failed to start.
- Initialization error within the Profinet communication software.
- Missing or corrupted Profinet configuration files.
- Insufficient system resources to run the Profinet controller.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Review the parameterization settings for the PROFINET firmware by examining the contents of the 'bas_cm_api.xml' file.
- 2
Verify that all required parameters within 'bas_cm_api.xml' are correctly configured according to the PROFINET specifications.
- 3
Compare the 'bas_cm_api.xml' file with a known good backup or reference configuration for correct structure and values.