Encoder Phase-Z Error
Omron · NJ/NX-series Machine Automation Controller
What does 04AF0000 hex mean?
A missing serial incremental encoder phase-Z pulse was detected. This means the encoder is not providing its reference zero-position pulse correctly, essential for accurate homing and absolute positioning.
Common Causes
- The encoder is faulty.
Repair Steps & Checklist
Click steps to track your progress.
- 1
Inspect the serial incremental encoder cable for physical damage, proper routing, and secure connections at both the encoder and the Omron NJ/NX controller's input module.
- 2
Verify the encoder's power supply voltage at its input terminals against the manufacturer's specifications to ensure stable operation.
- 3
Check the encoder configuration parameters within the Omron Sysmac Studio project, specifically verifying the encoder type, resolution, and Z-phase input settings.
- 4
Examine the mechanical coupling between the encoder and the motor shaft for looseness, slippage, or damage that could prevent accurate pulse generation.