F028

Autotuning fault

Schindler · Easy Altivar ATV310 Drive

What does F028 mean?

This ATV310 fault occurs when the drive's auto-tuning function fails to complete successfully. This can be caused by the motor not being properly connected, a motor phase loss during the tuning process, using a special motor type incompatible with standard autotuning, or the motor rotating during the tuning procedure.

Common Causes

  • Motor is not connected to the drive output during the autotuning process
  • Motor phase loss detected during the autotuning procedure
  • Special motor type that is not compatible with the drive's standard autotuning algorithm
  • Motor is rotating (e.g., being driven by the load) when autotuning is initiated

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check that the motor and drive are compatible for autotuning, referring to documentation.

  2. 2

    Verify that the motor is physically connected to the drive's output terminals during the autotuning process.

  3. 3

    If an output contactor is being used downstream of the drive, ensure it is closed and energized during auto-tuning.

  4. 4

    Check that the motor is completely stopped and uncoupled from the load, if possible, before initiating autotuning.

Browse all codes in this manual (37)
Verified technical data. Last updated: March 2026

Related Faults

Source: Schindler Easy Altivar ATV310 Drive
Schindler Error F028: Autotuning fault — Troubleshooting Guide | ErrorLib