F031
Incorrect configuration
Schindler · Easy Altivar ATV310 Drive
What does F031 mean?
This fault indicates that the drive's configuration is inconsistent. It can occur if an HMI block from a drive with a different rating is installed, or if the customer parameters currently loaded are not valid for the drive.
Common Causes
- HMI block replaced by an HMI block configured on a drive with a different rating.
- The current configuration of customer parameters is inconsistent or corrupted.
- Configuration data integrity issue during power-up or parameter changes.
Repair Steps & Checklist
Click steps to track your progress.
- 1
Return the drive to its factory settings to clear any inconsistent configuration data.
- 2
Retrieve and load a valid backup configuration if one is available and known to be compatible.
- 3
If the fault persists after reverting to factory settings, contact your local Schneider Electric representative for further assistance.
Verified technical data. Last updated: March 2026