91
Communication error between field-bus gateway and MOVIMOT®
SEW Eurodrive · MOVIMOT MM..C
What does 91 mean?
This fault is generated by the bus module and indicates an issue with the RS-485 communication link between the fieldbus gateway and the MOVIMOT® unit, typically stemming from electrical connection problems.
Common Causes
- Faulty electrical connection (RS-485) between the fieldbus gateway and MOVIMOT® (interrupted or switched cable).
Repair Steps & Checklist
Click steps to track your progress.
- 1
Check the electrical connection (RS-485) between the fieldbus gateway and MOVIMOT® for continuity and correct wiring.
- 2
Note: The fault automatically resets once the cause is removed; a reset via control word is not possible.
Verified technical data. Last updated: March 2026