Overcurrent in power section
Bosch Rexroth · IndraDrive C Drive Controllers
What does E8028 mean?
The current flowing through the drive's power section has exceeded its maximum safe limit. This is a critical warning that indicates an immediate risk of damage to the drive or motor.
Common Causes
- Short circuit in the motor windings or motor power cables.
- Motor or mechanical system experiencing a severe overload or mechanical blockage.
- Incorrect drive parameters (e.g., motor current limits, control gains) leading to instability.
- Faulty current measurement circuitry within the drive.
Repair Steps & Checklist
Click steps to track your progress.
- 1
Check motor windings and power cables for short circuits or ground faults using appropriate continuity and insulation tests.
- 2
Inspect the mechanical system for any binding, blockage, or excessive friction that could cause high motor current.
- 3
Verify all drive parameters related to motor control, current limits, and load conditions against the motor nameplate and application requirements.
- 4
Monitor the actual motor current during operation to identify when the overcurrent condition occurs.