F2018

Device overtemperature shutdown

Bosch Rexroth · IndraDrive C Drive Controllers

What does F2018 mean?

The drive controller or associated power electronics have reached a critical internal temperature, triggering a safety shutdown to prevent damage. This is a severe thermal event.

Common Causes

  • Inadequate cooling for the drive due to blocked vents, fan failure, or high ambient temperature.
  • Sustained operation at or above the drive's rated output current.
  • Internal thermal sensor malfunction or incorrect reading.
  • Failure of internal cooling components.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Allow the drive controller to cool down completely before attempting to reset the fault.

  2. 2

    Check the drive's cooling fan for proper operation. Verify airflow direction and ensure no obstructions in the heatsink or ventilation openings.

  3. 3

    Measure the ambient temperature around the drive and ensure it is within the specified operating range.

  4. 4

    Reduce the load on the drive if possible, or verify that the drive is correctly sized for the application's continuous and peak current requirements.

Browse all codes in this manual (66)
Verified technical data. Last updated: March 2026