F2036
Excessive position feedback difference
Bosch Rexroth · IndraDrive C Drive Controllers
What does F2036 mean?
The difference between the expected and actual position feedback values is excessively large. This indicates a significant discrepancy in position tracking, potentially due to a feedback error or mechanical issue.
Common Causes
- Loss or disturbance of position encoder signals.
- Mechanical play, backlash, or slippage in the drive train.
- Incorrect encoder scaling or gear ratio parameters.
- Faulty encoder or drive feedback monitoring circuit.
Repair Steps & Checklist
Click steps to track your progress.
- 1
Inspect all encoder cabling and connections for security, damage, and proper shielding. Verify encoder power supply.
- 2
Check the mechanical system for excessive backlash, loose couplings, or slippage in the belt/gear train.
- 3
Verify the encoder scaling, gear ratio, and other position feedback parameters in the drive match the mechanical system.
- 4
If using multiple encoders, compare their feedback values for consistency. Perform an encoder diagnostic test.
Verified technical data. Last updated: March 2026
Related Faults
Source: Bosch Rexroth IndraDrive C Drive Controllers