F3122

Safety related holding system: system error

Bosch Rexroth · IndraDrive MPx02

What does F3122 mean?

A general system error has occurred within the safety-related holding system. This system is responsible for safely holding the motor or axis in position, often through mechanical brakes. This fault indicates a critical failure in the holding mechanism's overall operation, requiring immediate attention to prevent unintended motion or dropping of loads.

Common Causes

  • Failure of the motor holding brake mechanism
  • Brake control circuit malfunction
  • Feedback sensor for brake status is defective
  • Internal safety module error affecting holding system control
  • Loss of power to the holding brake

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Inspect motor and brake control cables for damage, loose connections, and proper shielding between the drive and the motor/brake.

  2. 2

    Verify drive parameters related to the safety-related holding system (e.g., brake control, monitoring settings) for correct configuration as per machine documentation.

  3. 3

    Measure the resistance of the motor brake coil at the drive's output terminals (with power off and locked out) and compare to the motor's technical specifications.

Browse all codes in this manual (60)
Verified technical data. Last updated: March 2026

Related Faults

Source: Bosch Rexroth IndraDrive MPx02