The application file attempted to be loaded into the ACS880 drive is incompatible or corrupted, preventing successful loading. This fault cannot be reset, indicating a fundamental issue with the application software.
Click steps to track your progress.
Note that this fault cannot be reset directly; a power cycle may temporarily clear it but it indicates a deeper issue.
Verify the integrity of the application file being loaded. Re-download or obtain a new, known good copy if corruption is suspected.
Check the compatibility of the application file with the current drive firmware version; ensure all prerequisites are met.
Ensure the application file is correctly formatted and intended for the ACS880 series drive.
Contact ABB technical support with details of the application file, firmware version, and all event log data if the problem persists.