ACS880 · Primary Control Program Firmware
No motor speed feedback signal was received by the ACS880 drive. This indicates an issue with the feedback device (e.g., encoder, resolver), its cabling, or its configuration, which is critical for accurate motor control.
Click steps to track your progress.
Check parameter 90.41 Motor feedback selection to ensure the correct feedback source (e.g., FEN-11, FEN-21) is selected and enabled.
Inspect the physical connection of the motor feedback device (encoder/resolver) to the drive's interface module (FEN-xx) for looseness or damage.
Verify the wiring between the feedback device and the drive for continuity, correct pin assignments, and proper shielding.
Check the feedback device for proper operation and power supply; measure voltage at the device if possible.
Ensure the encoder/resolver interface module (FEN-xx) is correctly installed, seated, and configured according to the hardware manual.