ALM LED Blink (1:1)
Broken Wire or Noise (Subsequent Unit)
Fanuc · R-30iB Mate + Mate Plus Robot
What does ALM LED Blink (1:1) mean?
The red ALM LED blinks with a 1:1 duty cycle (0.5s ON / 0.5s OFF), indicating a broken wire or poor cable connection between the unit of interest (JD1A connector) and a subsequent unit (JD1B connector). Electromagnetic noise around the cable is also a potential contributing factor to this communication issue.
Common Causes
- A broken wire or significant electrical noise is disrupting communication with a subsequent unit or module.
- The signal integrity on the communication bus to a connected device (e.g., I/O expander, remote axis) has been compromised.
- This could be due to damaged cabling, poor shielding, or interference from external electrical sources.
- The control system is unable to reliably receive or transmit data from the affected downstream unit.
Repair Steps & Checklist
Click steps to track your progress.
- 1
Check for a defective cable or a poor cable connection between JD1A on the unit of interest and JD1B on a unit subsequent to that unit.
- 2
Check to see if there is noise present around the cable.
Verified technical data. Last updated: March 2026
Related Faults
Source: Fanuc R-30iB Mate + Mate Plus Robot