Fronius · Primo GEN24
The Fronius Primo GEN24 208-240 inverter has detected an overcurrent condition on its AC output, meaning the current flowing into the grid is higher than permitted. This fault indicates a potential short circuit or overload condition in the AC connection or grid.
Click steps to track your progress.
Disconnect the Fronius Primo GEN24 208-240 inverter from the AC grid and visually inspect the AC connection cables and terminals for any signs of damage, short circuits, or loose connections.
Check the AC cables between the inverter and the grid connection point for insulation breakdown or damage.
Verify the ratings of external AC overcurrent protection devices (circuit breakers, fuses) are appropriate for the inverter's output.
Ensure no external loads are causing a short circuit or extreme overload condition directly at the inverter's output if operating in a microgrid setup.
If the issue persists after external checks, this may indicate an internal fault with the inverter; contact Fronius service.