Fronius · Primo GEN24
The Fronius Primo GEN24 208-240 inverter, configured for operation with a Smart Meter, has lost communication with the device. This fault specifically refers to configurations where a Smart Meter is essential for the operating mode, thus halting normal inverter function.
Click steps to track your progress.
Reconfirm all communication cabling (e.g., RS485) between the Fronius Primo GEN24 208-240 inverter and the Smart Meter is correctly installed, free from damage, and securely terminated.
Check the power supply to the Fronius Smart Meter to ensure it is receiving adequate voltage and is operational.
Verify that the Modbus address and baud rate configured in the inverter match the settings of the Smart Meter.
Inspect the Smart Meter's status LEDs for any indications of error or power loss.
Power cycle the inverter and the Smart Meter in sequence to reset the communication interface.