404

Inverter with battery: no communication

Fronius · Primo GEN24

What does 404 mean?

The Fronius Primo GEN24 208-240 inverter, configured to operate with a battery, has lost communication with the battery system. This prevents any battery charging or discharging, effectively disabling the energy storage function.

Common Causes

  • No communication with the battery.
  • Wiring fault (e.g. incorrect or loose cable, crossed data lines).
  • Battery not powered.
  • Incorrect battery address or settings.
  • Battery system internal fault.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check all communication cables (e.g., CAN bus, RS485) between the Fronius Primo GEN24 208-240 inverter and the battery management system (BMS) for proper connection and integrity.

  2. 2

    Confirm that the battery system is powered on, not in sleep mode, and its status indicators (LEDs) are normal.

  3. 3

    Verify the communication protocol settings (e.g., CAN ID, Modbus address) within the inverter's interface align with the battery manufacturer's specifications.

  4. 4

    Inspect the communication cable for any physical damage, breaks, or incorrect pinouts.

  5. 5

    Perform a controlled shutdown and restart of both the inverter and the battery system as per their respective manuals to reset communication.

Browse all codes in this manual (60)
Verified technical data. Last updated: April 2026

Related Faults

102AC voltage too high103AC voltage too low1030WSD Open
Source: Fronius Primo GEN24
Open Manual (Page 149)Search more codes in this manual