The Fronius Primo GEN24 208-240 inverter has detected an excessive current flowing to or from the connected battery system on the DC side. This indicates a potential short circuit in the battery DC wiring or an issue with the battery itself.
Click steps to track your progress.
Disconnect the battery using the DC disconnector and visually inspect all battery cables, terminals, and connectors for signs of damage or short circuits.
Check the battery's operating status and any error indicators on the battery itself. Consult the battery manual.
Measure the voltage at the battery terminals to ensure it is within the normal operating range.
Verify that the DC cables connecting the battery to the Fronius Primo GEN24 208-240 inverter are correctly sized and free from insulation damage.
If the battery system permits, check for internal fault codes or diagnostics within the battery management system (BMS).